Medium hot air blower zone without door, 4.4 kW, 560 mm wide, IP25, for Electrolux green&clean dual rinse rack type dishwashers. PNC 535138.
Marine galley equipment by vessel
60 Hz Ship Dishwashers
60 Hz Ship Dishwashers on this page: 15 Electrolux Professional models for merchant, passenger and offshore galleys running a 60 Hz supply. Eight are zone modules that lengthen a rack line, four are rack type dishwashers and three are hood types. Thirteen belong to the green&clean series, nine carry a 440 V label, and connected loads run from 4.4 kW to 42.5 kW.

Large drying zone with door for green&clean dual rinse rack machines, 890 x 825 mm footprint, 8.5 kW at 440 V/3 ph/50/60 Hz. PNC 535139.
Corner drying zone module, 872 x 872 mm footprint, 8.5 kW at 440 V/3 ph/50/60 Hz for green&clean dual-rinse rack dishwashers.
Medium pre-wash zone module, 560 x 825 x 1785 mm, 7.37 kW, 440 V/3 ph/60 Hz, for green&clean dual rinse rack type dishwashers. PNC 535131.
Rack conveyor dishwasher CC0FW1, 200 racks/3600 dishes per hour with 0.9 l/rack rinse at max speed, 440 V/3 ph/60 Hz, green&clean dual rinse.
Rack conveyor dishwasher CC0FW2, 200 racks/3600 dishes per hour with steam abatement and 42.5 kW installed power, 440 V/3 ph/60 Hz, green&clean.
Rack conveyor dishwasher CC0FW0 with steam abatement, 150 racks/2700 dishes per hour, 42.1 kW at 440 V/3 ph/60 Hz, green&clean dual rinse.
Electrolux Professional Hood Type Dishwasher 504265 – green&clean, hood type
Hood type green&clean dishwasher, 9.9 kW at 440 V/3 ph/60 Hz with 24 l tank and 12 l boiler, IPX5 and <63 dBA. PNC 504265.
872 x 872 mm green&clean corner drying zone, 8.5 kW, IP25, for dual rinse rack-type dishwashers, PNC 535180.
Corner drying zone module, 872 x 872 mm, 8.5 kW, IP25, for green&clean dual-rinse rack conveyors. PNC 535099.
Electrolux Professional Hood Type Dishwasher 506060 – green&clean, Hood Type Dishwasher (60Hz)
Hood type dishwasher 506060, 9.9 kW, 400 V/3 ph/60 Hz, 24 l tank and 12 l boiler, 746 x 755 mm footprint, green&clean series.
Electrolux Professional Hood Type Dishwasher 505080 – green&clean, hood type Dishwasher
Hood type dishwasher 505080, 9.9 kW at 440 V/3 ph/60 Hz with 24 l tank and 12 l boiler from the green&clean series.
Medium hot air blower rack zone without door, 4.4 kW, 560 mm wide, IP25, for Electrolux dual rinse rack type dishwashers. PNC 535135.
Rack conveyor dishwasher 535127, 150 racks/2700 dishes per hour at 42 kW, 440 V/3 ph/60 Hz for high-volume marine wash-up.
Large drying zone module with door, 8.5 kW, 890 x 825 x 1785 mm, IP25. Electrolux green&clean PNC 535136.
What the 60 Hz Ship Dishwashers list is built around
Fifteen cards, one manufacturer, and a clear bias towards volume: more than half the list is zone modules, the sections that turn a rack dishwasher into a full wash line. Four rack type dishwashers serve as base machines and three hood types cover smaller crews. There are no undercounter units and no domestic-style machines, because a ship galley feeding a full crew three or four times a day rarely has use for them.
Every model is from Electrolux Professional and thirteen of the fifteen belong to the green&clean series. That single-brand line-up makes the 60 Hz Ship Dishwashers grid easy to combine: zones, base machines and hood types share the same design family, so a line can be assembled from cards on one page.
Which ship supplies do these machines accept?
Five models record 440-480 V at 60 Hz, more than any other band. On most large merchant ships the main board is exactly that, a 440 V three-phase system at 60 Hz, so these machines take their supply straight from the ship's distribution. Four further models are recorded at 380-415 V, 60 Hz.
| Recorded supply | Models | Fleet relevance |
|---|---|---|
| 440-480 V, 60 Hz | 5 | Main board voltage on most large merchant ships |
| 380-415 V, 60 Hz | 4 | Ships that distribute 380 V or 400 V at 60 Hz |
| 380-415 V, 50 Hz | 4 | Same product numbers also serve 50 Hz ships |
| 440-480 V, 50 Hz | 2 | Dual-rated builds for 440 V boards at 50 Hz |
Six of the fifteen are also rated at 50 Hz, so an owner whose fleet mixes both standards can keep one product number across several hulls. By voltage label the list shows 440 V on nine cards, 400 V on three and 380 V on two. Nine cards record a three-phase connection, and none is recorded as single-phase. The reasoning behind matching frequency on pump-driven machines is set out in our note on matching ship frequency, worth reading before any converter is proposed.
Planning a rack line with zone modules on a cargo or passenger ship
Eight zone modules sit in this list, each made for the Dual Rinse Rack Type Dishwasher base. Drying section 535136 is the large version, closed by a door. Blower section 535135 is medium sized, open-fronted, and drives hot air across the racks. Both cards record 380-415 V three-phase at 50 and at 60 Hz.
The base machine is rack type dishwasher 535127, a green&clean dual rinse unit that its listing gives as 150 racks per hour on electric 60 Hz supply. A typical line runs from a loading table through any pre-wash zone, then the base machine's wash and dual rinse sections, then drying or blowing before the unloading end. The direction, left to right or right to left, is fixed by the galley layout and should be stated when ordering so that modules and tables match. Competing base units sit on the rack-type listing for marine galleys.
What does a 42.5 kW dishwasher mean for the ship's switchboard?
Four machines on this page pass the 40 kW mark, and the highest plate figure is 42.5 kW. The remaining loads are modest: two up to 5 kW and nine between 5 and 10 kW, starting at 4.4 kW.
A 40 kW consumer in the galley belongs in the ship's electrical load analysis as a named item, not inside a general galley allowance. Most of that power heats the wash tank, the rinse boiler and the drying air. On a cargo ship with two generators sharing the hotel load, the dishwasher fill after breakfast can coincide with the galley ranges and the provision store compressors, so its breaker, cable and protection are sized for the plate rating. A hot-fill connection from the ship's calorifier shortens the heat-up period but does not change what the circuit must carry.
Hood type 505080 for a smaller crew
Three hood type dishwashers cover ships where a full rack line would be oversized. The green&clean 505080 carries a three-phase 440-480 V rating at 60 Hz, so it connects to the same board as the rest of the galley. A crew member loads racks from a dirty table, lowers the hood, and passes the clean rack out the other side.
For a commercial dishwasher 60 hz on a vessel with a smaller crew, a hood machine with two tables uses a fraction of the deck length of a rack line and far less power than the 40 kW class. It also keeps the wash area manageable for a single steward.
Getting long machines aboard and into place
Recorded widths run from 560 mm to 2,080 mm across all fifteen cards. The longest assemblies are rarely lifted in as one piece; modules are delivered separately and joined in the galley.
The access route matters on a ship as much as the final position. Watertight doors, stairway landings and the provisioning crane's reach all limit what can be brought aboard. Once in place, a machine must be secured against rolling and pitching, connected to a drain that leads to the grey water system, and given space at the front for racks and service access.
When a 60 Hz ship machine is the wrong pick
A ship that runs a 50 Hz board and has no intention of changing should look at the full ship dishwasher range, which includes 50 Hz builds not shown here; the six dual-rated models are the only crossover. A small vessel with a crew of a few people, or a yacht-style pantry, will find these machines oversized, and the 60 Hz yacht dishwasher list carries 600 mm front-loading and undercounter units instead.
Platforms and support vessels have their own selection. The offshore dishwasher page groups the machines listed for offshore galleys at both frequencies.
What to put in a ship dishwasher enquiry
Begin with the ship's particulars that affect the wash area: the kind of ship, how many people eat aboard and how many sittings each meal needs. Then the electrical details: main board voltage, 60 Hz frequency, three-phase arrangement, and whether the galley is fed directly or through a transformer. Give the length of deck available for a rack line, its direction of travel, and the access route to the galley. Add the hot water source and the drain connection, and list how many machines are needed in galley, mess and pantry. A message through the enquiry page for ship galleys is enough to start, and the wider Electrolux galley range is on the manufacturer's brand page.
Last reviewed by the Vista Marine galley engineering team.
Questions about 60 hz ship dishwashers
Do these ship dishwashers connect directly to a 440 V board?
Many do. Nine of the fifteen cards carry a 440 V label, and five record the full 440-480 V, 60 Hz band. Hood type 505080 is one example, recorded as three-phase. Other models in the list are rated 380-415 V, so check the plate data on each card against the ship's distribution before ordering.
Can the same model be used on 50 Hz ships in the fleet?
Six of the fifteen models are also rated for 50 Hz, recorded as 380-415 V, 50 Hz on four cards and 440-480 V, 50 Hz on two. Zone modules 535135 and 535136 are examples, rated at both frequencies. A 60 Hz-only model on a 50 Hz board would run its pumps slower than designed.
What is a dishwasher zone module?
A zone module is a section that bolts onto a Dual Rinse Rack Type Dishwasher to extend the line, for example drying section 535136 or blower section 535135. It does not wash on its own. The base rack machine and its modules are ordered together, with the direction of travel fixed by the galley layout.
Which machine suits a ship with a small crew?
A hood type dishwasher is usually the better fit. Three are listed here, including green&clean 505080 at 440-480 V, 60 Hz. It works between a dirty and a clean table, needs far less deck length than a rack line, and draws much less power than the machines rated above 40 kW.
How much power does the largest machine need?
The top rating on this page is 42.5 kW, and four machines exceed 40 kW. Most of the load heats the tank, the rinse boiler and the drying air. A machine of that size needs a dedicated circuit and its own entry in the ship's electrical load analysis, sized to the plate rating rather than an average draw.
Related searches
Request a quotation for 60 hz ship dishwashers
Send the vessel type, supply voltage, frequency and phase and the quantities, and our team will come back with a specification and quotation.